The 2-port EtherCAT junction enables configuration of EtherCAT star topologies. A modular EtherCAT star can be realised by using several EP1122 units in a station. Individual devices or complete EtherCAT strands can be connected at the junction ports. The EtherCAT junctions are connected via shielded M8 screw connectors with direct display of link and activity status. The Run LED indicates the status of the EP1122. Through TwinCAT and other suitable EtherCAT masters the EP1122 also supports coupling and uncoupling of EtherCAT strands during operation (Hot Connect).
| Technical data | EP1122-0001 |
|---|---|
| Number of EtherCAT ports | 2 |
| Task within EtherCAT system | coupling of EtherCAT junctions |
| Data transfer medium | EtherCAT cable |
| Distance between stations | 100 m (100BASE-TX) |
| Protocol | EtherCAT |
| Data transfer rates | 100 Mbaud |
| Nominal voltage | 24 V DC (-15 %/+20 %) |
| Distributed clocks | – |
| Configuration | not required |
| Bus interface | 2 x M8, shielded, screw type |
| Power supply | from E-bus |
| Sensor supply | – |
| Current consumption | typ. 220 mA |
| Weight | approx. 165 g |
| Operating/storage temperature | 0…+55 °C/-25…+85 °C |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27/29 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. | IP 65/66/67 (conforms to EN 60529)/variable |
| Approvals | CE, UL, Ex |
![]() |
![]() |